How to tell DN-UC-4DMA from DN-UC-4DMB?

 

In general they are identical in circuit functions. Earlier 4DMA was with thermo-resistant ceramic IC while 4DMB with commercial grade plastic-packed IC, however, currently theyare both devised the same IC element thanks to the introduction of SMT. Now as a user you choose among them to the color of switchboard - 4DMA comes in black tone while4DMB in silver white tone (penal and casing). There the same type of products are as follow: DN-UC-6DMA, DN-UC-5DMA, DN-UC-3DMA, DN-UC-2DMA, DN-UC-6DMB, DN-UC-5DMB, DN-UC-3DMB, DN-UC-2DMB, DNK-UC-6AM, DNK-UC-5AM and DNK-UC-4AM.

..............................................................................................................................................................................
What are the basic functions commonly found in e-counters CN6DM, CN6D6M and CN6AM?
  Model CN6DM:
6-digit red LED conducts the following computations with the input from 2-set counting signals:a. single count up, b. dual count up, c. count up and count down, d, auto-judge to count up/down.
Allows choosing decimal point and fine adjust of output reset time within 0.1 - 9.9sec.
Allows to magnify or minify every count signal with multiplier and to display counting rate per minute.

Model CN6D6M: In general the functions are in common with CN6DM but with additional functions of totalizing and batching.
Model CN6AM: In general the functions are in common with CN6DM but with additional function of 2 sets of forecast outputs.
..............................................................................................................................................................................
All KONDA ELECTRONIC DN-UC counters with sock handy for use however just with 12-terminal connection.Now what should I do when my existing connector is with 14-terminal connection?
  In general KONDA ELECTRONIC series counters come with sockets of 12-terminal spec. However, those with sockets for 14- or 18-terminal spec are available now. All you have to do is indicate us the socket terminal spec desired for counters of any brand and you will have what meet your need exactly.
..............................................................................................................................................................................
Can I change DN-UC-4DMA into a Counter with totalizer directly?
  Sure, by all means. Please put DN-UC-4D Main body and Socket apart (without disconnect wires from connection terminals), then replace the main body with CN6D6M counter main with totalizer by pushing its plugs into the socket holes.
Read the user's instructions before use and then set parameters (output reset time, decimal point, count ratio, count up/downK)
..............................................................................................................................................................................
Does KONDA ELECTRONIC offer Timer Relays?
  For sure! KONDA ELECTRONIC timers come in 2 sizes - 72x72mm and 48x48mm.
Microprocessor timer such as TN4DM and TS4DM for setting interval from 0.01sec to 9999hr. and timer relays are about to release to the market right upon approval for CE certification.
..............................................................................................................................................................................
How long is the Warranty?
  Every piece of KONDA ELECTRONIC product enjoys a one-year warranty.
..............................................................................................................................................................................
What Is the Warranty Detail?
  For every piece of KONDA ELECTRONIC product you purchase you enjoy a one-year warranty from date of purchase on the following conditions: Replace with new one reconditioned one with functions identical to new one's or repair totally free of charge in case the flaw is resulted from material or production deficiency. However, the warranty excludes any damage caused by illegal dissembling or remodeling or repair or non-recommended installation, or damages resulted from force majeur, human error or natural disasters.